Olivetti d-Copia 3500MF Service Manual page 103

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U052
Setting the fuser motor control
Description
Enters the sensor data values described on the supplied sheet provided when the loop sensor is
replaced and performs correction processing for the fuser motor.
Purpose
To perform when replacing the loop sensor or paper conveying unit.
Method
1. Press the start key.
2. Select the item.
Set Loop Sensor
Loop Sensor Control
Set Loop Sensor Valid
Chk Loop Sensor
Method: [Set Loop Sensor]
1. Select [Scanning Board1].
2. Enter the sensor data value of supplied sheet DATA1 using
the +/- keys.
3. Select [Scanning Board2].
4. Enter the sensor data value of supplied sheet DATA2 using
the +/- keys.
5. Press the start key. The value is set.
Setting: [Loop Sensor Control]
1. Select the item.
2. Select On or Off.
Display
No.1
No.2
No.3
No.4
No.5
No.6
3. Press the start key. The setting is set.
Y113350-5
Display
Enter the data value for loop sensor
Set the loop sensor detection control
Sets the presence or absence of the loop sensor
Display the data value for loop sensor
Sensor detection On/Off setting at 125 to 250 mm from
the top of paper
Sensor detection On/Off setting at 250 to 290 mm from
the top of paper
Sensor detection On/Off setting at 300 to 330 mm from
the top of paper
Sensor detection On/Off setting at 350 to 370 mm from
the top of paper
Description
Description
Description
1-3-41
2LL/2LJ/2LH
How to read the sensor data value
(e.g.)
1
2
3
4
5
6
7
8
9
0
3 6 4
Initial setting
On
On
On
On
On
On
Sevice Manual