Item No.
U411
8. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning.
Method: [DP FaceDown (Chart2)]
1. Place the specified original for acquiring gamma target data (P/N: AVGR05133T) on the
platen, and press the start key.
2. Place the specified original for acquiring matrix target data (P/N: 303JX57020) on the platen,
and press the start key.
When normally completed, [OK] is displayed.
3. Select the item.
Display
All
Input
MTF/Gamma
Matrix
[Input]
1. Select [Input].
2. Set a specified original (P/N: AVGR11211F) on the DP face down.
3. Press the start key. Auto adjustment starts.
[MTF/Gamma]
1. Select [MTF/Gamma].
2. Set a specified original (P/N: AVGR05133T) on the DP face down.
3. Press the start key. Auto adjustment starts.
[Matrix]
1. Select [Matrix].
2. Set a specified original (P/N: AVGR05134Q) on the DP face down.
3. Press the start key. Auto adjustment starts.
When [ALL] is selected, the adjustment of [Input], [MTF/Gamma] and [Matrix] can be executed at
once. When adjusting, place the three specified originals on the DP face down, and then press
the start key.
Set the original AVGR05134Q, and then place AVGR05133T and AVGR11211F in order on the
top of the original.
Y113350-5
Description
Description
Executing the adjustment in the DP scan-
ning section (second side) for magnifica-
tion, leading edge timing, center line, MTF
filter, input gamma and matrix
Executing the adjustment in the DP scan-
ning section (second side) for magnifica-
tion, leading edge timing and center line
Executing the adjustment in the DP scan-
ning section (second side) for MTF filter
and input gamma
Executing the adjustment in the DP scan-
ning section (second side) for matrix
1-3-145
2LL/2LJ/2LH
Original to be used
for adjustment (P/N)
AVGR11211F/
AVGR05133T/
AVGR05134Q
AVGR11211F
AVGR05133T
AVGR05134Q