Olivetti d-Copia 3500MF Service Manual page 153

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U161
Setting the fuser control temperature
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper,
or solve a fuser problem on thick paper.
Method
1. Press the start key.
2. Select the item to be set.
Warm Up
Print
Setting: [Warm Up]
1. Select the item to be set.
2. Change the setting value using the +/- keys.
Display
Ready
(Center)
Ready
(Edge)
Drive
(Center)
Drive
(Edge)
Wait
(Center)
Wait
(Edge)
3. Press the start key. The value is set.
Y113350-5
Display
Control temperature except at printing
Control temperature during printing
Description
Control temperature at display-
ing Ready (Center)
Control temperature at display-
ing Ready (Edge)
Stable temperature during driv-
ing (Center)
Stable temperature during driv-
ing (Edge)
Stable temperature during halt
(Center)
Stable temperature during halt
(Edge)
Description
Description
Setting
range
130 to 200
(°C)
100 to 200
(°C)
130 to 200
(°C)
100 to 200
(°C)
130 to 200
(°C)
100 to 200
(°C)
1-3-91
2LL/2LJ/2LH
Initial setting
35ppm 45ppm 55ppm
110
110
110
110
110
110
155
160
170
150
155
165
155
160
170
160
160
160
Sevice Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 4500mfD-copia 5500mf

Table of Contents