Item No.
U246
Setting: [Width Up HP/Width Down HP]
1. Select [Width Up HP] or [Width Down HP].
2. Change the setting value using the +/- keys or numeric keys.
Adjustment of upper side registration home position -15 to 15
Adjustment of lower side registration home position
3. Press the start key. The value is set.
4. Press the stop key. The screen for selecting a maintenance item No. is displayed.
5. Enter maintenance mode U240 and select [Booklet], then [Width Test(A3)].
The width guides of the center-folding unit will move to A3-size position.
6. Pull the center-folding unit, insert paper between the guides and check that paper is abut the
guides.
7. Repeat the above adjustment until paper is properly in position.
Setting: [Staple Pos]
1. Select [Staple Pos1], [Staple Pos2] or [Staple Pos3].
2. Change the setting value using the +/- keys or numeric keys.
Adjustment of booklet stapling position for
A4/Letter size
Adjustment of booklet stapling position for
B4/Legal size
Adjustment of booklet stapling position for
A3/Ledger/8K size
When staples are placed too far right (sample 1), decrease the preset value. When staples
are placed too far left (sample 2), increase the preset value.
Reference value: within ± 2 mm
3. Press the start key. The value is set.
Service Manual
Description
Description
Description
Sample 1
Figure 1-3-22
1-3-118
Setting
range
-15 to 15
Setting
range
-15 to 15
-15 to 15
-15 to 15
2 mm
2LL/2LJ/2LH
Initial
Change in
setting
value per step
0
0.34 mm
0
0.34 mm
Initial
Change in
setting
value per step
0
0.32 mm
0
0.32 mm
0
0.32 mm
2 mm
Sample 2
Y113350-5