U485
Setting the image processing mode
Description
Sets the detection level for scanning printed matter outputted with the confidential document
guard function. Also, sets the process PDF images are rotated.
Purpose
To change the detection level when the confidential document guard is not printed well for detec-
tion in scanning. Also, changes the process of how PDF images are rotated.
Method
1. Press the start key.
2. Select the item.
Conf. Doc. Detection
PDF Rotation
Setting: [Conf. Doc. Detection]
1. Change the setting value using +/- keys or numeric keys.
Conf. Doc.
Detection
A smaller value raises the detection sensitivity but increases the possibility of false detection.
A larger value lowers the detection sensitivity but decreases the possibility of false detection.
2. Press the start key. The value is set.
Setting: [PDF Rotation]
1. Change the setting value using +/- keys or numeric keys.
0
1
2
Initial setting: 0
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Service Manual
Display
Confidential document guard detection level
Processing the rotation of PDF images
Display
Confidential document guard detection
level
Display
Assigns the image rotation with the internal parameter
Assigns the image rotation with the actual image
Assigns the image rotation with the internal parameter
(CTM rotation)
Description
Description
Description
Description
1-3-160
2LL/2LJ/2LH
Setting
Initial
range
setting
1 to 5
1
Y113350-5