Item No.
U131
Adjusting the toner sensor control voltage
Description
Adjusts the toner sensor control voltage.
Purpose
If control values are not correctly retrievable due to the EEPROM of the developer unit failure,
etc., use manual adjustment and obtain a temporary control value.
Method
1. Press the start key.
2. Select the item to be set or displayed.
Manual
Auto
Mode
Setting: [Manual]
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.
Display
Control(K)
3. Press the start key. The value is set.
Displaying: [Auto]
1. The current setting is displayed.
Default(K)
Control(K)
Setting: [Mode]
1. Select the item to be set.
Manual
Auto
Initial setting: Auto
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Service Manual
Display
Toner sensor control voltage manual adjustment
Toner sensor control voltage auto adjustment
Switching the manual adjustment and auto adjustment
Description
Toner sensor control voltage
Display
Reference value for toner sensor control voltage
Toner sensor control voltage after correction
Display
Toner sensor control voltage manual adjustment
Toner sensor control voltage auto adjustment
Description
Description
Setting
range
0 to 255
Description
Description
1-3-78
2LL/2LJ/2LH
Initial setting
35ppm 45ppm 55ppm
107
120
128
Y113350-5