Item No.
U464
Setting: [Leaving Time]
1. Change the setting value using the +/- keys or numeric keys.
Display
Time(min)
2. Press the start key. The value is set.
Setting: [Driving Time]
1. Change the setting value using the +/- keys.
Display
Time(sec)
2. Press the start key. The value is set.
Setting: [Timing]
1. Change the setting value using the +/- keys.
Display
Time(sec)
2. Press the start key. The value is set.
Setting: [Target Value]
1. Select the item.
2. Change the setting value using the +/- keys or numeric keys.
Display
Thickness(K) Bias for addition in toner thick
Gamma(K)
3. Press the start key. The value is set.
Method: [Calib]
1. Select [Execute].
2. Press the start key. Calibration is executed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Service Manual
Description
Description
Setting the standard time of sleep mode
Description
Setting the drive standard time
Description
Setting the drive standard time of con-
tinuous print
Description
layer calibration
Light amount calibration
1-3-158
Setting range
0 to 480 (min)
Setting range
300 to 3000 (s)
Setting range
300 to 3600 (s)
Initial setting
Setting
range
35ppm 45ppm 55ppm
0 to 1000
790
0 to 500
350
2LL/2LJ/2LH
Initial
setting
480
Initial
setting
300
Initial
setting
3600
760
760
350
350
Y113350-5

Advertisement