Olivetti d-Copia 3500MF Service Manual page 458

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Connector
Pin
YC6
1
Connected to
2
feed PWB 1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Service Manual
Signal
GND
JOB_SET
JOB_MOT_REM
JOB_MOT_CLK
JOB_MOT_DIR
JOB_OPEN_SENS
JOB_SOL_REM
GND
EXIT_REAR_FAN_
L
EXIT_REAR_FAN_
H
ZEROC
SUB_HEAT
MAIN_HEAT
FSR_CL
FSR_MOT_REM
FSR_MOT_CLK
FSR_MOT_RDY
GND
FSR_MOT_DIR
FSR_MOT_BRK
MPF_TABLE
MPF_WID1
MPF_WID2
MPF_WID3
MPF_LNG
3.3V3
MPF_PPR_SET
MPF_LIFT_UP
MPF_LIFT_DOWN
MPF_JAM
MPF_CL_REM
MPF_LIF2
MPF_LIFT1
GND
I/O
Voltage
-
-
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC (pulse) JSEM clock signal
O
0/3.3 V DC
I
0/3.3 V DC
O
0/24 V DC
-
-
O
0/24 V DC
O
0/24 V DC
O
0/3.3 V DC (pulse) Zero-cross signal
O
0/3.3 V DC
O
0/3.3 V DC
-
-
O
0/3.3 V DC
O
0/3.3 V DC (pulse) FUM clock signal
O
0/3.3 V DC
-
-
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
0/24 V DC
O
0/24 V DC
O
0/24 V DC
-
-
2-3-16
Description
Ground
Job separator set signal
JSEM: On/Off
JSEM drive switch signal
JSOCS: On/Off
JSFSSOL: On/Off
Ground
ERFM: On/Off
ERFM: On/Off
FH2: On/Off
FH1: On/Off
Not used
FUM: On/Off
FUM ready signal
Ground
FUM drive switch signal
FUM break signal
MPTSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPWSW: On/Off
MPPLSW: On/Off
3.3 V DC power to FPWB1
MPPS: On/Off
MPLS1: On/Off
MPLS2: On/Off
MPFS: On/Off
MPPFCL: On/Off
MPLM: On/Off
MPLM: On/Off
Ground
2LL/2LJ/2LH
Y113350-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 4500mfD-copia 5500mf

Table of Contents