Item No.
U039
Adjusting the magnification
Description
Adjusts the magnification of the printing.
Purpose
Make the adjustment if the magnification in the auxiliary scanning direction is incorrect.
Caution
Adjust the magnification in the following order.
U039
Method
1. Press the start key.
2. Press the system menu key.
3. Press the start key to output a test pattern.
4. Press the system menu key.
5. Select the item to be adjusted.
Display
Sub Scan
Adjustment: [Sub Scan]
1. Change the setting value using the +/- keys or numeric keys.
Increasing the setting makes the image longer, and decreasing it makes the image shorter.
2. Press the start key. The value is set.
Completion
Press the stop key. The indication for selecting a maintenance item No. appears.
Service Manual
Description
U065
U070
(P.1-3-47)
(P.1-3-52)
Description
Magnification in the auxiliary
scanning direction
Figure 1-3-6
1-3-38
Setting
Initial
range
setting
-1 to 1
0
350 ± 1.4 mm
2LL/2LJ/2LH
Change in
value per step
0.1 %
Y113350-5