Olivetti d-Copia 3500MF Service Manual page 503

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Connector
Pin
YC1
35
Connected to
36
engine PWB
37
38
39
40
41
42
43
44
45
46
47
48
49
50
YC2
1
Connected to
2
paper feed
3
motor
4
5
6
7
YC3
1
2
Connected to
paper length
3
switch 1/2,
4
paper width
switch 1/2, lift
5
motor 1/2,
6
paper gauge
7
sensor 1(U)/
(L) and paper
8
gauge sen-
9
sor 2(U)/(L)
10
11
12
Y113350-5
Signal
I/O
PICK_SOL1_RET
PICK_SOL1_REM
CAS2_P0
CAS2_LIFT_UP
CAS2_EMPTY
PICK_SOL2_RET
PICK_SOL2_REM
GND
REG_SENS
FEED1_SENS
BEND_SENS
MID_MOT_PH
MID_MOT_REM(
ROL_CL)
MID_MOT_CLK
MID_MOT_PD
ASIST_CL1
FEED_MOT_GAI
N
FEED_MOT_DIR
FEED_MOT_RDY
FEED_MOT_CLK
FEED_MOT_REM
GND
24V2
CAS1_LNG1
CAS1_LNG2
GND
CAS1_LNG3
CAS1_WID
GND
CAS2_LNG1
CAS2_LNG2
GND
CAS2_LNG3
CAS2_WID
GND
Voltage
I
0/24 V DC
I
0/24 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/24 V DC
I
0/24 V DC
-
-
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC (pulse) MM clock signal
I
0/3.3 V DC
I
0/24 V DC
-
-
O
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) PFM clock signal
O
0/24 V DC
-
-
O
24 V DC
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
-
-
I
0/3.3 V DC
I
0/3.3 V DC
-
-
2-3-61
Description
PUSOL1: On/Off (RET)
PUSOL1: On/Off (ACT)
FS2: On/Off
LS2: On/Off
PS2: On/Off
PUSOL2: On/Off (RET)
PUSOL2: On/Off (ACT)
Ground
RS: On/Off
PCS: On/Off
RDS: On/Off
MM control signal
MM/MCL: On/Off
MM control signal
ASCL1: On/Off
Not used
PFM drive switch signal
PFM ready signal
PFM: On/Off
Ground
24 V DC power to PFM
PLSW1: On/Off
PLSW1: On/Off
Ground
PLSW1: On/Off
PWSW1: On/Off
Ground
PLSW2: On/Off
PLSW2: On/Off
Ground
PLSW2: On/Off
PWSW2: On/Off
Ground
2LL/2LJ/2LH
Sevice Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 4500mfD-copia 5500mf

Table of Contents