Olivetti d-Copia 3500MF Service Manual page 273

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Code
Contents
3210
CIS lamp error
When input value at the time
of CIS illumination does not
exceed the threshold value
between 5 s.
3300
Optical system (AGC) error
After AGC, correct input is not
obtained at CCD.
3310
CIS AGC error
After AGC, correct input is not
obtained at CIS.
3500
Communication error
between scanner and ASIC
An error code is detected.
Scanner sequence error
3600
Y113350-5
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
CIS and DPSHD PWB (YC2)
DPSHD PWB (YC3) and DP relay PWB
(YC2)
Defective CIS.
Replace the CIS and check for correct oper-
ation.
Defective DPSHD
Replace the DPSHD PWB and check for
PWB.
correct operation.
Defective DP relay
Replace the DP relay PWB and check for
PWB.
correct operation.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
CCD PWB (YC2) and ISC PWB (YC9)
ISC PWB (YC3) and main PWB (YC11)
Defective exposure
Replace the LED lamp PWB and check for
lamp.
correct operation.
Defective CCD
Replace the CCD PWB and check for cor-
PWB.
rect operation.
Defective ISC
Replace the ISC PWB and check for correct
PWB.
operation.
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-38).
Defective CIS.
Replace the CIS and check for correct oper-
ation.
Defective DPSHD
Replace the DPSHD PWB and check for
PWB.
correct operation.
Defective DP relay
Replace the DP relay PWB and check for
PWB.
correct operation.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
ISC PWB (YC3) and main PWB (YC11)
Defective ISC
Replace the ISC PWB and check for correct
PWB.
operation.
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-381-5-38).
Defective ISC
Replace the ISC PWB and check for correct
PWB.
operation.
1-4-31
2LL/2LJ/2LH
Check procedures/
corrective measures
Sevice Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 4500mfD-copia 5500mf

Table of Contents