Olivetti d-Copia 3500MF Service Manual page 145

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U140
Setting: [Mag DC]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
K
3. Press the start key. The value is set.
Setting: [Mag AC]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
K
3. Press the start key. The value is set.
Setting: [Sleeve Freq]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
Normal
3. Press the start key. The value is set.
Setting: [Sleeve Duty]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
Normal
3. Press the start key. The value is set.
Setting: [Mag Duty]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
Normal
3. Press the start key. The value is set.
Y113350-5
Description
Developer magnet roller DC bias 0 to 255
Description
Developer magnet roller AC bias 0 to 255
Description
Developer sleeve roller frequency 0 to 6200
Description
Developer sleeve roller duty
Description
Developer magnet roller duty
1-3-83
Description
Setting
range
Setting
range
Setting
range
Setting
range
0 to 99
Setting
range
0 to 99
2LL/2LJ/2LH
Initial setting
35ppm 45ppm 55ppm
148
148
180
Initial setting
35ppm 45ppm 55ppm
101
101
199
Initial setting
35ppm 45ppm 55ppm
5345
5511
5345
Initial setting
35ppm 45ppm 55ppm
37
37
68
Initial setting
35ppm 45ppm 55ppm
37
37
68