Olivetti d-Copia 3500MF Service Manual page 219

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U464
Setting: [Time Interval]
1. Change the setting value using the +/- keys or numeric keys.
Display
Time(sec)
2. Press the start key. The value is set.
Setting: [Mode]
1. Select the item.
Short
Normal
Long
Custom
Auto
Initial setting: Normal
2. Press the start key. The setting is set.
Setting: [On/Sleep Out]
1. Select On or Off.
On
Off
Initial setting: On
2. Press the start key. The setting is set.
Setting: [AP/NE]
1. Select On or Off.
On
Off
Initial setting: On
2. Press the start key. The setting is set.
Y113350-5
Setting the interval time of calibration
Display
Setting the calibration execution mode: short
Setting the calibration execution mode: normal
Setting the calibration execution mode: long
Setting the calibration execution mode: custom
Setting the calibration execution mode: auto
Display
Executes calibration if fuser temperature is less than 50C/
122F at power-up or recovery from auto sleep mode
Executes calibration regardless of fuser temperature at power-
up or recovery from auto sleep mode
Display
Paper interval calibration at the time of calibration/near end
after toner feed is carried out
Paper interval calibration at the time of calibration/near end
after toner feed is not carried out
Description
Description
Description
Description
Description
1-3-157
2LL/2LJ/2LH
Setting
Initial
range
setting
0 to 9999 (s)
480