Item No.
U136
Setting toner near end detection
Description
Sets the level that indicates the number of sheets that can be printed from occurrence of toner
near end to toner empty.
Purpose
To change the setting to advance detection of near end if the interval from toner near end to toner
empty seems too short.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the value using the +/- or numeric keys.
Display
K
Increasing the setting makes the interval from toner near end to toner empty longer.
Decreasing the setting makes the interval from toner near end to toner empty shorter.
If 0 is set, toner near end will not be detected.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Service Manual
Description
Description
Setting the level of toner
1-3-80
2LL/2LJ/2LH
Setting
Initial
range
setting
0 to 9
3