Olivetti d-Copia 3500MF Service Manual page 215

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U425
Method: [Chart2]
1. Press the start key.
2. Select the item.
CCD
DP
CIS
Method: [CCD]
1. Select the item to be set.
N875
N475
N125
C
M
Y
R
G
B
Adjust Original
2. Select the item to be set.
L
a
b
3. Enters the value that is indicated on the back of the chart using the +/- keys or numeric keys.
4. Press the start key. The value is set.
Y113350-5
Display
Entering the target values of the chart (P/N: AVGR05131K)
used for adjustment
Entering the measurement value of the chart (P/N:
AVGR11211F) used for adjustment
Execution is not required
Display
Setting the N875 patch for the original for adjustment
Setting the N475 patch for the original for adjustment
Setting the N125 patch for the original for adjustment
Setting the cyan patch for the original for adjustment
Setting the magenta patch for the original for adjustment
Setting the yellow patch for the original for adjustment
Setting the red patch for the original for adjustment
Setting the green patch for the original for adjustment
Setting the blue patch for the original for adjustment
Setting the main and auxiliary scanning directions
Display
Setting the L value
Setting the a value
Setting the b value
Description
Description
Description
Description
1-3-153
2LL/2LJ/2LH
Setting range
0.0 to 100.0
-200.0 to 200.0
-200.0 to 200.0
Sevice Manual