Olivetti d-Copia 3500MF Service Manual page 185

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U251
Checking/clearing the maintenance counter
Description
Displays and clears or changes the maintenance count and automatic grayscale adjustment
count.
Purpose
To verify the maintenance counter count and automatic grayscale count. Also to clear the count
during maintenance service.
Setting
1. Press the start key.
2. Select the item to be changed.
3. Change the setting using the +/- keys or numeric keys.
Display
M.Cnt A
M.Cnt HT
4. Press the start key. The value is set.
Clearing
1. Select [Clear].
2. Press the start key. The setting value is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Y113350-5
Description
Description
Count value for maintenance cycle (kit A)
Automatic grayscale adjustment count
1-3-123
2LL/2LJ/2LH
Setting range
0 to 9999999
0 to 9999999
Sevice Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 4500mfD-copia 5500mf

Table of Contents