Olivetti d-Copia 3500MF Service Manual page 89

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U021
Memory initializing
Description
Initializes all settings, except those pertinent to the type of machine, namely each counter, ser-
vice call history and mode setting. Also initializes backup RAM according to region specification
selected in maintenance item U252 Setting the destination.
Purpose
To return the machine settings to their factory default.
Method
1. Press the start key.
2. Select [Execute].
3. Press the start key. All data other than that for adjustments due to variations between
machines is initialized based on the destination setting.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
* : An error code is displayed in case of an initialization error.
When errors occurred, turn main power switch off then on, and execute initialization using
maintenance item U021.
Error codes
Y113350-5
Codes
0001
Entity error
0002
Controller error
0020
Engine error
0040
Scanner error
Description
Description