1-5-4 Image formation section

(1) Detaching and refitting the inner unit

Procedure
1. Open the front cover.
2. Remove toner container.
3. Remove the waste toner box tray by lift-
ing upwards and from the right side.
4. Remove the screw and then open the
connector cover.
5. Release the wire saddle.
6. Remove the connector.
Service Manual
Waste toner
box tray
Connector
cover
Screw
Connector
cover
Connector
1-5-26
1
2
Figure 1-5-45
Wire saddle
Figure 1-5-46
2LL/2LJ/2LH
Y113350-5