Olivetti d-Copia 3500MF Service Manual page 154

Hide thumbs Also See for d-Copia 3500MF:
Table of Contents

Advertisement

Item No.
U161
Setting: [Print]
1. Select the item to be set.
2. Change the setting value using the +/- keys.
Display
Full Speed
Print(Center)
Full Speed
Print(Edge)
Duplex Shift
(Center)
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U163
Resetting the fuser problem data
Description
Resets the detection of a service call code indicating a problem in the fuser section.
Purpose
To prevent accidents due to an abnormally high fuser temperature.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key. The fuser problem data is initialized.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
Service Manual
Description
Description
Temperature at maximum print
speed (Center)
Temperature at maximum print
speed (Edge)
Temperature at duplex printing
(Center)
1-3-92
Initial setting
Setting
range
35ppm 45ppm 55ppm
130 to 200
160
(°C)
100 to 200
170
(°C)
-20 to 20
0
(°C)
2LL/2LJ/2LH
165
175
175
185
5
10
Y113350-5