1-5-8 Drive section

(1) Detaching and refitting the drum drive unit

Procedure
1. Remove the developer unit (see page
1-5-28).
2. Remove the drum unit (see page 1-5-
29).
3. Remove the rear upper cover and the
rear lower cover (see page 1-5-52).
4. Remove the feed PWB 1 assembly (see
page 1-5-59).
5. Remove the connector.
6. Release the wire saddle.
7. Remove three screws.
8. Remove the drum drive unit.
*: Do not have a shaft part alone when
you carry drum drive unit. (Have the
housing.)
*: Put support on the tip of the shaft so
that the shaft may become the horizon-
tal when you put drum drive unit on the
table etc.
Y113350-5
Wire
saddle
Connector
Screw
Screw
Screw
1-5-57
Figure 1-5-95
(Shaft portion)
Drum drive unit
(housing portion)
Figure 1-5-96