Table 94: Unidirectional Link Detection Commands - Edge-Core ECS4120-28F Reference Manual

28/52-port layer 2+ gigabit ethernet switch
Hide thumbs Also See for ECS4120-28F:
Table of Contents

Advertisement

17
udld detection-
interval
UniDirectional Link Detection
Commands
The switch can be configured to detect and disable unidirectional Ethernet fiber or
copper links. When enabled, the protocol advertises a port's identity and learns
about its neighbors on a specific LAN segment; and stores information about its
neighbors in a cache. It can also send out a train of echo messages under
circumstances that require fast notifications or re-synchronization of the cached
information.

Table 94: UniDirectional Link Detection Commands

Command
Function
udld detection-interval
Sets the amount of time the switch remains in
detection state after discovering a neighbor
udld message-interval
Configures the message interval between UDLD
probe messages
udld recovery
Automatically recovers from UDLD disabled port
state after a period specified by the udld recovery-
interval command
udld recovery-interval
Specifies the period after which to automatically
recover from UDLD disabled port state
udld aggressive
Sets UDLD to aggressive mode on an interface
udld port
Enables UDLD on a port
show udld
Shows UDLD configuration settings and operational
status
This command sets the amount of time the switch remains in detection state after
discovering a neighbor. Use the no form to restore the default setting.
Syntax
udld detection-interval detection-interval
no detection-interval
detection-interval – The amount of time the switch remains in detection
state after discovering a neighbor through UDLD. (Range: 5-255 seconds)
Default Setting
5 seconds
Command Mode
Global Configuration
– 481 –