Outputting Alarms To The Terminal - Huawei Quidway S9300 Configuration Manual

Terabit routing switch device management
Table of Contents

Advertisement

Quidway S9300 Terabit Routing Switch
Configuration Guide - Device Management
2.
Step 2 Configuring the channel through which alarms are output to the console
1.
2.
Step 3 Enabling terminal display
1.
2.
----End

5.4.7 Outputting Alarms to the Terminal

By outputting alarms to the terminal, you can view the operating status of the device on the
terminal.
Context
Do as follows on the switch configured with the information center:
Procedure
Step 1 Configuring the alarms to be output through the channel
1.
2.
Issue 03 (2011-12-29)
The system view is displayed.
Run:
info-center source { module-name | default } channel { channel-number | channel-
name } [ trap { state { off | on } | level severity }
Alarms are added to the information channel.
By default, the timestamp format of debugging information is date.
Run:
info-center console channel { channel-number | channel-name }
The channel through which alarms are output to the Console is configured.
By default, alarms are output to the Console through Channel 0.
Run:
quit
Back to the user view.
Do as follows on the switch configured with the information center, run:
terminal monitor
Terminal display is enabled.
Run:
terminal trapping
Displaying alarms on the terminal is enabled.
Run:
system-view
The system view is displayed.
Run:
info-center source { module-name | default } channel { channel-number | channel-
name } [ trap { state { off | on } | level severity }
Alarms are added to the information channel.
By default, the timestamp format of alarms is date.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Information Center Configuration
*
]
*
]
70