Outputting Alarms To The Alarm Buffer - Huawei Quidway S9300 Configuration Manual

Terabit routing switch device management
Table of Contents

Advertisement

Quidway S9300 Terabit Routing Switch
Configuration Guide - Device Management
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
info-center channel channel-number name channel-name
The information channel specified by the channel-number is named as channel-name.
----End

5.4.4 Outputting Alarms to the Alarm Buffer

By default, alarms are output to the alarm buffer through a default channel. You can configure
alarms to be output through a specific channel.
Context
Do as follows on the switch configured with the information center:
Procedure
Step 1 Configuring the alarms to be output through the channel
1.
2.
Step 2 Configuring the channel through which alarms are output to the alarm buffer
1.
2.
----End
Issue 03 (2011-12-29)
Run:
system-view
The system view is displayed.
Run:
info-center source { module-name | default } channel { channel-number | channel-
name } [ trap { state { off | on } | level severity }
Alarms are added to the information channel.
By default, the timestamp format of alarms is date.
Run:
info-center trapbuffer [ channel { channel-number | channel-name } ]
The alarm buffer is set to receive information.
Run:
(optional)info-center trapbuffer [ channel {
*
| size buffersize ]
The channel through which alarms are output to the alarm buffer is configured.
After the information center is enabled, alarms default to be output through Channel 3 to
the alarm buffer and the alarm buffer can contain 256 pieces of information.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Information Center Configuration
*
]
channel-number | channel-name }