Data Preparation
To complete the configuration, you need the following data:
l
l
l
l
l
l
Procedure
Step 1 Configure routing protocols to make the switch and log server routable. (The detailed procedure
is not mentioned here.)
Step 2 Configure the channel for outputting logs.
# Enable the information center.
<Quidway> system-view
[Quidway] info-center enable
Step 3 Name the channel.
# Name the channel through which logs are output.
[Quidway] info-center channel 6 name loghost1
Step 4 Configure the channel through which logs are output.
# Configure the module enabled to output logs and the severity levels of logs allowed to be
output.
[Quidway] info-center source fib channel loghost log level notifications
[Quidway] info-center source ip channel loghost log level notifications
[Quidway] info-center source ppp channel loghost1 log level warnings
[Quidway] info-center source aaa channel loghost1 log level warnings
Step 5 Configure the source interface that sends logs.
# Configure the source interface that sends logs.
[Quidway] info-center loghost source vlanif 10
Step 6 Configure the logs to be output to a specified log host.
# Specify Server 1 as the log server and Server 3 as the backup log server to receive the logs
from the FIB module and the IP module. The logs are output in English, by Local2.
[Quidway] info-center loghost 10.1.1.1 public-net facility local2 language english
[Quidway] info-center loghost 10.1.1.2 public-net facility local2 language english
Issue 03 (2011-12-29)
Enable the information center.
Name the tunnel.
Specify the module enabled to output logs.
Configure the channel for outputting logs.
Configure the source interface that sends logs.
Configure the log host.
IP address of the log host
Information channel number
Name of the channel through which logs are output
Module enabled to output logs
Information severity level
Language in which the log is output