Configuring Bits Signals To Participate In The Bmc Calculation; Configuring Attributes For The Ptp Clock Source - Huawei Quidway S9300 Configuration Manual

Terabit routing switch device management
Table of Contents

Advertisement

Quidway S9300 Terabit Routing Switch
Configuration Guide - Device Management
12.7.2 Configuring BITS Signals to Participate in the BMC
Calculation
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
ptp clock-source { bits0 | bits1 } { off | on }
BITS signals can be configured to participate in or do not participate in the BMC calculation.
----End

12.7.3 Configuring Attributes for the PTP Clock Source

Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
ptp clock-source { local | bits0 | bits1 }time-source time-source
The type of the time source to be traced is configured.
Step 3 Run:
ptp clock-source { local | bits0 | bits1 }clock-accuracy clock-accuracy
The clock accuracy of the time source is configured.
Step 4 Run:
ptp clock-source { local | bits0 | bits1 }clock-class clock-class
The class of the time source is configured.
Step 5 Run:
ptp clock-source { local | bits0 | bits1 }priority1 priority1
The value is set for priority1 of the time source.
Step 6 Run:
ptp clock-source { local | bits0 | bits1 }priority2 priority2
Issue 03 (2011-12-29)
NOTE
The attribute of the time-source can be configured only on the grandmaster clock. The external time source
to which the device connects should be configured with corresponding parameters. The mapping between
the time-source-value and external time source is on the Command Reference.
NOTE
When clock-class-value is smaller than 128, the device cannot be slave clock.