Emergency Stop Circuit Driver Failure; Top Stop Circuit Driver Failure - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800
Problem:
This error indicates that the light curtains are connected with TWO HAND
ONLY firmware installed in WPC.
Remedy:
Be sure that the correct version of firmware is installed in WPC. It should
be one that expects to work with light curtains. Because there are several
versions of firmware available, consult Wintriss Tech Support if you are
not sure which is the correct one for your application..

Emergency stop circuit driver failure

Problem:
The driver circuitry which controls the emergency stop (E-Stop) input
circuitry has a failure. This error can also be generated by the second
processor.
Remedy:
Reset. Check the E-Stop wiring. If the error persists, contact Wintriss
Tech Support for immediate assistance or replacement .

Top stop circuit driver failure

Problem:
The driver circuitry which controls the top stop input circuitry has a
failure. This error can also be generated by the second processor.
Remedy:
Reset. Check the Top Stop wiring. If the error persists, contact Wintriss
Tech Support for immediate assistance or replacement.