4. You can add more arcs by pressing F6-"Add a New Arc" again.
5. If you want to adjust one of the arcs, press F7-"Select Arc" one or more times, until the
arc you want to adjust turns green (see next figure). Use the cursor keys to adjust the
arc.
6. Press RESET when you have set the arcs you want.
NOTICE
To delete an ON/OFF output event for this cam channel you must delete channel settings
(page 313) for this channel and make the ON/OFF settings again.
Inactive arcs
are gray

Selecting a Channel and Making a Timed Output Setting

NOTICE
MAXIMUM NUMBER OF TIMED CHANNELS PER TOOL
Each tool can have up to four timed-output cam channels.
A timed output setting means that you set the crankshaft angle at which you want the channel
to turn ON and the dwell duration time in milliseconds (in other words, how long you want
the channel to stay on). This makes the channel "ON-duration" independent of press speed.
SmartPAC 2 Program Mode
Figure 5 - 34. Selected and Inactive Arcs
Chapter 5
Selected (active) arc
listed here
and indicated by
green color
on circle diagram
page 309