1126800
Wiring the Overrun Sensor Magnetic Switch
NOTICE
You can run both the resolver wires and the overrun limit switch cable through the same
conduit. If you do this, wait to cut the cable and wires until both the resolver and the overrun
limit switch are installed.
Run the magnetic switch's cable through conduit to the WPC. Connect the wires to terminal
blocks on the WPC control board, as shown in the table below. See also the Figure 3 wiring
diagram at the end of the manual. You will install the overrun sensor magnet as part of the
initialization process, after you finish the installation procedures in this chapter.
Table 2 - 1. WPC Overrun Sensor Magnetic Switch Wiring
Pin #
Connection
23
+24 VDC
24
Overrun input to WPC
25
Ground
Page 46
SmartPAC 2 with WPC Integration
Wire color
White or Clear
Chapter 2
Installing SmartPAC 2 and WPC
Red
Black