SmartPAC 2 with WPC Integration
Table 2 - 3. Resolver Wiring on SmartPAC 2
* Shown for clockwise rotation, facing shaft.
For counterclockwise, swap black and yellow wires

Connecting Communications Between SmartPAC 2 and WPC

1.
Locate TB105 on the SmartPAC 2 board (Figure 2 - 39, page 162) and TB501 on the
WPC Interface Board (Figure 2 - 38, page 161). See Figure 1 at the end of this manual
for wiring.
2.
Run the four-conductor shielded cable through the same flexible liquid-tight low-
voltage conduit (referenced above) from SmartPAC to WPC.
Installing SmartPAC 2 and WPC
PIN # on TB101
212 (GND)
213 (S1)
214 (S2)
215 (R1)
216 (S3)
217 (R2)
218 (S4)
Chapter 2
Wire Color
Shield
[terminate to ground stud
nearest entry to enclosure]
no connection
Black*
Green
Red
Yellow*
Orange
Brown