Table 4 - 8. Switch 5 Setting For Prior Act Timing - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

SmartPAC 2 with WPC Integration
Switch 5 – Prior Act Timing for Automatic Single Stroke and Continuous on
Demand
NOTICE
After you change switch settings, power down the SmartPAC 2/WPC. Power it up again to
enable the new settings. If you do not this, the previous switch settings will remain in effect.
Option Switch 5 sets the prior act timing for Automatic Single Stroke mode and for
Continuous on Demand mode. The switch in the OPEN position selects the shorter prior act
time for both modes (30 seconds/1 minute, respectively). The switch in the CLOSED
position selects the longer prior act time for both modes (5 minutes/10 minutes, respectively).
Refer to the table below .
For more information about Automatic Single Stroke mode, see "Operating the Press in
Automatic Single Stroke Mode," page 373. For more information about Continuous on
Demand mode, see "Operating the Press in Continuous on Demand," page 377.
Set Switch 5 in the Press Control Option Switches screen, Figure 4 - 33, page 241.

Table 4 - 8. Switch 5 Setting for Prior Act Timing

Option Switch 5 Setting
OPEN
CLOSED
SmartPAC 2 Initialization Mode
Prior Act Timing for
Automatic Single Stroke
30 seconds
3 minutes
Chapter 4
1126800
Prior Act Timing for
Continuous on Demand
1 minute
10 minutes
page 245