Setting Switches

NOTICE
• Make sure that you program all eight Press Option switches properly at SmartPAC.
• After you change switch settings, power down the SmartPAC 2/WPC. Power it up again to
enable the new settings. If you do not this, the previous switch settings will remain in effect.
1. In the Press Control Option Switch menu, "SW1" (for Switch #1) will be highlighted on
the display.
2.
Notice that Switch one is in the OPEN state. Press ENTER to toggle between OPEN
and CLOSED. Set the switch according to your application (see sections below).
3.
After you have set the correct state for SW1, press RESET once to confirm that
selection. Use the cursor keys to select "SW2."
4.
Repeat steps 2 and 3 for the remaining switches (SW2 through SW8).
5.
If you are done, press RESET to return to the main menu. If not, proceed to "Setting
operator mode settings" below.
NOTICE
To e-mail a copy of this screen, see "Screen Capture," page 199.
Switches 1 and 2 – Overrun Limit Switch Setting
NOTICE
After you change switch settings, power down the SmartPAC 2/WPC. Power it up again to
enable the new settings. If you do not this, the previous switch settings will remain in effect.
Set these switches in the Press Control Option Switches screen, Figure 4 - 33, page 241,
according to the top stop angle you set at "Set Top Stop Angle and Install Overrun Magnet,"
starting on page 107. See also the installation instructions for the Overrun Limit Sensor
Magnet, starting on page 116.
Table 4 - 5. Switch 1 and Switch 2 Settings for Different Top Stop Angles
Top Stop Angle
Switch 1 Setting
Switch 2 Setting
Overrun Limit Switch
Test Angle
(unzeroed resolver angle)
Page 242
Less
241 ° ° ° °
than
to
240 ° ° ° °
270 ° ° ° °
CLOSED
CLOSED
CLOSED
OPEN
270 °
300 °
Chapter 4
SmartPAC 2 with WPC Integration
271 ° ° ° °
Greater
than
to
301 ° ° ° °
300 ° ° ° °
OPEN
OPEN
CLOSED
OPEN
330 °
359 °
SmartPAC 2 Initialization Mode