Honeywell SmartPAC 2 User Manual page 43

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

SmartPAC 2 with WPC Integration
Specifications: SmartPAC 2 with WPC
Motor
Additional WPC
Forward and reverse contacts
Inputs
Shadow light curtains (2)
Checks proper functioning at every stroke initiation and stop
Customized Status Codes
Four for E-stop
Three for top stop
One pair cross-checked inputs for E-stop
One pair cross-checked inputs for E-stop/lockout
DSV
WPC Outputs
2 monitored relays; rating 4 A @ 120 VAC; for emergency and top stopping
Lockout
1 monitored relay, rating 4 A @ 120 VAC; for de-energizing motor and other devices
under critical conditions
Auxiliary Stop Output
Allows to stop auxiliary equipment during an interrupted stroke
SmartPAC 2
DiProPAC* provides up to 16 die protection sensor inputs
Options
ProCamPAC* provides up to 16 programmable cam switch output channels
SmartPAC 2
Options,
continued
SmartPAC 2
AutoSetPAC* or WaveFormPAC* 10.25" x 12" x 4" (260 x 305 x 102 mm)
Options,
continued
SmartPAC 2
SFI* ServoFeed Interface integrates servofeed
Options,
RamPAC * 10.25" x 12" x 4" (260 x 305 x 102 mm)
continued
SmartPAC 2
ProPAC* 12.3" x 14" x 4.3" (312 x 356 x 109 mm)
Options,
continued
Introduction to SmartPAC 2
Power for electronic sensors (NPN only): 12 VDC min, 100 mA total
Sensor inputs 1 through 4 and 9 through 12: Low impedance
Sensor inputs 5 through 8 and 13 through 16: High impedance
Optional sensor inputs for all 1-16: Low impedance (<1000 Ω)
DiPro Sensor Interface, DSI 2
DiPro RCB: 4.56" x 2.56" x 4.06" (116 x 65 x 103 mm)
DiProPAC sensor-disabled output: open collector, 8 mA max.
Programmable cam output assembly (NEMA 12; holds up to 8 outputs)
Enclosure: 9" x 11" x 3.5" (229 x 279 x 89 mm) shock-mounted
Relay SPDT 0-4 A resistive @ 240V
DC solid state SPST 2A @ 5-60 VDC
AC solid state SPST 1A @ 70-250 VAC
2 or 4 strain link inputs
Ability to store high, low, and repeatability setpoints with tool number
Display, adjust, recalculate "auto" setpoints and display actual load
Display and save load signatures
With WaveFormPAC: Up to 4 windows to monitor tonnage at points other than the
peak
Automatically sets shut height and counterbalance and cushion pressures
Provides up to 16 analog, NPN or PNP inputs
Ability to store high, low, and repeatability setpoints with tool number
Display and adjust manual or auto setpoints and display actual values
Monitor in-die dimensions and other process parameters
Chapter 1
1
: 5.88" x 5.41" x 3.42" (149 x 137 x 87 mm)
1126800
page 21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents