Reset Mode; Changing Passwords - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

SmartPAC 2 with WPC Integration
NOTICE
DO NOT SET INIT PASSWORD TO "MUST BE USED" UNTIL YOU HAVE CHECKED
YOUR PASSWORDS
Field upgraded SmartPAC 2s may have different passwords than those listed in this manual.
If you do not know the initialization password and change Init password to "Must be used"
you will not be able to access the initialization menu again.
3.
Press RESET to save your choice and return to the Initialization menu.
Examples
You want to prevent loading a tool number in Run mode. Set the security access for this
item to Program Mode Only. Highlight the access level next to "Load Tool #." Press ENTER
one or more times until "PROGRAM MODE ONLY" appears. Press RESET. Now a tool can
be loaded only when the Prog/Run key is switched to Prog.
You have the password option and want only certain individuals to adjust the cams . Set
Adjust Cams to "PASSWORD REQUIRED," and tell those individuals the password. Highlight
the access level next to "Adjust Cams." Press ENTER one or more times until "PASSWORD
REQUIRED" appears. Press RESET. Now the cams cannot be adjusted without the user
entering the correct password.

Reset Mode

Set the Reset mode security access with care. If you set access to "Program mode only" or
"Password required," personnel cannot reset SmartPAC 2 in Run mode after a malfunction
that stops the press. If you want the operator to reset the machine after errors, select
"Program and Run Modes." If you want one person to record or be aware of all faults that
occur, give that person the Program/Run key, and set the access to Program mode only. He
or she would be able to reset faults by turning the key to "Program" and pressing the RESET
key. Turning the key back to "Run" allows the press to run again.

Changing Passwords

If it has the password option, your SmartPAC 2 has three passwords that secure different
parts of its operation:
Init. password allows access to the initialization menu
General password allows access to all other menus and settings, except for PM
Monitor (see next bullet).
PM password allows access to the PM (preventive maintenance) Monitor setup in
Program mode. See "Appendix B – SmartPAC Preventive Maintenance (PM)
Monitor (Optional)".
Tool Template password allows access changes to the Tool Template, described on
page 280.
SmartPAC 2 Initialization Mode
Chapter 4
1126800
page 255

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents