1126800
Green Constant
When you set a sensor input to "green constant," the sensor must turn on before the ready
signal begins and turn off after the ready signal ends. That is, it must stay actuated constantly
during the ready signal. However, the sensor must turn off, at least momentarily, outside the
ready signal.
KEY
= Ready
Signal
= Sensor
ON
Sensor staysON
during entire ready
Green
signal and goes OFF
Constant
at least momentarily
Sensor
outside the ready
signal.
Figure 1 - 5. How SmartPAC 2 Interprets Signals From a Sensor Set to
Page 16
not allowed
OK
(press stops)
TDC
TDC
BDC
BDC
Sensor goes OFF
before ready signal
ends.
Stop signal sent
immediately.
"Green Constant"
Chapter 1
SmartPAC 2 with WPC Integration
not allowed
not allowed
(press stops)
(press stops)
TDC
BDC
Sensor never goes
Sensor never goes
OFF outside ready
ON.
signal.
Stop signal sent at
Stop Signal sent at
beginning of ready
end of ready signal.
signal.
Introduction to SmartPAC 2
TDC
BDC