Continuous Mode Test Without Light Curtain(s)

DANGER
!
INJURY DURING TESTING
Keep all personnel away from the press during testing.
Ensure there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
!
DANGER
IMPROPER SAFEGUARDING
• Install safeguarding devices as needed to ensure operator safety. Follow the machine
guarding requirements of OSHA standard 1910.217 and any other regulations and standards
that apply.
• Ensure that guarding is properly installed to prevent access to the machine over, under or
around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
WARNING
!
ELECTRIC SHOCK HAZARD WHEN WORKING INSIDE ENCLOSURE WITH POWER ON
• DO NOT touch electrical connections or circuit boards.
• Ensure that this test is performed by qualified personnel.
Failure to comply with these instructions could result in death or serious injury.
NOTICE
Refer to the WPC LED map, Figure B at the end of the manual.
• If your press runs in continuous mode and does not have a light curtain, perform the
test below.
• If your press runs in continuous mode and has a light curtain, perform the test in the
previous section.
• If your press does not run in continuous mode, make sure the wiring is disconnected
from the "Continuous" position on the stroke select switch. Cover the "CONT" label
on your control. Go to the next applicable test in this chapter.
1. Set the STROKE SELECT switch to CONT (Continuous).
NOTICE
CONTROL BOARD LEDS
At this point, the "SNGL STK SEL" LED should be off and the "CONT SEL" should be lit.
Installing SmartPAC 2 and WPC
Chapter 2
1126800
page 149