Wiring Wpc User Inputs - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800

Wiring WPC User Inputs

DANGER
!
USER INPUTS 1 THROUGH 7 NOT SUITABLE FOR SAFETY USE
DO NOT use inputs 1 through 7 as part of any personnel protection system. These inputs
are not control reliable.
Failure to comply with these instructions could result in death or serious injury.
DANGER
!
USER INPUTS ADD DELAY TO STOPPING TIME
DO NOT connect light curtains or other presence-sensing devices to any user inputs.
Cross-checked input pairs (8 & 9 and 10 & 11), though control reliable, are suitable only for
such applications as connecting to safety switches used with interlocking barrier guards.
Failure to comply with these instructions could result in death or serious injury.
DANGER
!
CROSS-CHECKED INPUT PAIRS WIRED INCORRECTLY
Wire and use input pairs 8 & 9 and 10 & 11 as instructed in this manual. These inputs are
control reliable only if correctly wired in pairs according to the instructions on page 52.
Failure to comply with these instructions could result in death or serious injury.
DANGER
!
INPUT STOP TYPE DIFFERENT FROM PREVIOUS VERSIONS OF WPC
Be sure to wire the WPC inputs according to the table below and the instructions in this
manual. With WPC firmware version 3.91 and higher, some of the inputs operate differently
from previous versions.
Failure to comply with these instructions could result in death or serious injury.
WARNING
!
PRESS DOES NOT STOP WHEN USER INPUT ACTUATES
• Remove the jumper from the main board connectors when you wire a user input. WPC
comes from the factory with the inputs bypassed by jumpers. If you do not remove the
appropriate jumper, WPC will not receive the signal from the input.
• Perform checkout procedures to ensure that the user inputs are wired correctly. Check after
installation to make sure WPC responds correctly when the user input faults.
Failure to comply with these instructions could result in death or serious injury.
WPC has eleven user inputs, two pairs of which are cross-checked so they are control reliable
when wired correctly to safety devices. You can use these cross-checked input pairs to
connect such devices as interlocked barrier guards to WPC, but you must never connect light
curtains or other presence-sensing devices to the inputs. See DANGER notice, above.