Customized Status Codes - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800

Customized Status Codes

DANGER
!
USER INPUTS 1 THROUGH 7 ARE NOT CONTROL RELIABLE
Do not use inputs 1 through 7 as part of any personnel protection system.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
USER INPUTS 8 THROUGH 11 ARE CONTROL RELIABLE ONLY IF CORRECTLY
WIRED IN PAIRS
Wire and use input pairs 8 & 9 and 10 & 11 as instructed in this document.
Failure to comply with these instructions will result in death or serious injury.
NOTICE
You can display the status of the user interlocks from Initialization mode. See "Using the
WPC Input Status Display," page 420.
Problem:
These error codes indicate failures that have occurred to auxiliary
equipment that you connected to WPC, such as lubrication systems.
Codes 50 and 58 are related to the cross-checked user input pairs (see
table, below, and also refer to codes 17 and 18, which are also related to
the user inputs). For more information about the user inputs, see pages 52
in the Installation chapter and page 225 in the Initialization chapter.
Remedy:
Check the auxiliary equipment that signaled the stop (see "Wiring WPC
User Inputs," page 52 in Chapter 2). Correct the problem. Reset
SmartPAC. If the error does not go away, contact Wintriss Tech Support.
Page 400
50 through 58
Chapter 7
SmartPAC 2 with WPC Integration
SmartPAC 2 Fault Messages