Foot Operation, Continuous Mode

DANGER
!
IMPROPER SAFEGUARDING
Ensure that the machine guarding system is installed and maintained according to OSHA
standard 1910.217, ANSI B11.1, ANSI B11.19 and any other regulations and standards that
apply. Ensure that guarding is properly installed to prevent access to the machine over,
under or around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
INCORRECT INSTALLATION
Shadow light curtains must be properly installed and connected to WPC in order to use
FOOT TRIP or FOOT CONTROL modes.
Failure to comply with these instructions will result in death or serious injury.
To operate the press in the foot continuous mode, perform the following steps.
Turn the Stroke Select switch to OFF. Set the mode to FOOT. Turn the Stroke Select switch
to CONT and then press the PRIOR ACT switch. While the PRIOR ACT LED is lit (for
eight seconds), depress the foot switch.
The press will run in continuous as long as the foot switch is depressed. If the foot switch is
released, the press will top stop. If you remove your foot from the foot switch and the ram
top-stops, you will have to press the PRIOR ACT switch again and then depress the foot
switch again while the LED is illuminated to initiate another stroke.
The press will operate continuously while the foot switch is depressed. However, the ram
will stop if any of the following situations occur:
• a system fault is detected
• you press the EMERGENCY STOP / RESET switch
• you press the Top Stop switch
• the light curtain is blocked during the non-muted portion of the stroke
NOTICE
If the Interrupted Stroke message flashes on the display, WPC has automatically changed
to Two-hand Maintained mode. You must depress and hold the run buttons to complete the
stroke and clear the Interrupted Stroke. (see "Interrupted Stroke," page 364) Foot Switch will
not work while the Interrupted Stroke message is on.
Page 376
SmartPAC 2 with WPC Integration
Chapter 6
SmartPAC 2 Run Mode