Honeywell SmartPAC 2 User Manual page 110

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800
Table 2 - 7. Making Connections to Relays
Module
How to connect
Relay
one wire to C; one wire to N/O or N/C; polarity does not matter
DC Solid State
– to C; + to N/O
AC Solid State
one wire to C; one wire to N/O; polarity does not matter
TB303
CHAN 8
CHAN 7
N/C C N/O
N/C C N/O
Figure 2 - 24. Connector TB302 and TB303 for Wiring Relays to Equipment
WARNING
!
RELAY REMAINS ENERGIZED DUE TO INCORRECT SUPPRESSOR INSTALLATION
Ensure that suppressors are correctly installed. They must not be installed across the relay
contacts inside the cam outputs enclosure. If a suppressor is installed across the relay
contacts and it fails shorted, the equipment controlled by that relay will remain energized all
the time.
Failure to comply with these instructions could result in death or serious injury.
10. You must install arc suppressors across each inductive load (motors, relays, coils, etc.)
that is connected to an output relay. Suppressors are supplied with each relay. The
suppressors reduce electrical noise and will extend the life of the relays. Find the
suppressors supplied with the modules.
11. Install the suppressors across the load and as close to the load as possible. Attach
suppressors by connecting leads across existing terminals or junction points. See the
following illustration for the correct way to install them.
Page 88
TB302
CHAN 6
CHAN 5
N/C C N/O
N/C C N/O
N/C C N/O
Chapter 2
SmartPAC 2 with WPC Integration
CHAN 4
CHAN 3
CHAN 2
N/C C N/O
N/C C N/O
Installing SmartPAC 2 and WPC
Type
SPDT
SPST
SPST
CHAN 1
N/C C N/O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents