Foot Operation, Single Stroke Mode

DANGER
!
IMPROPER SAFEGUARDING
Ensure that the machine guarding system is installed and maintained according to OSHA
standard 1910.217, ANSI B11.1, ANSI B11.19 and any other regulations and standards that
apply. Ensure that guarding is properly installed to prevent access to the machine over,
under or around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
INCORRECT INSTALLATION
Shadow light curtains must be properly installed and connected to WPC in order to use
FOOT TRIP or FOOT CONTROL modes.
Failure to comply with these instructions will result in death or serious injury.
You can single stroke the press in one of two foot modes — foot trip or foot control. The
mode is set using Option Switch 3. (See "Switch 3 – One-hand Control or Foot Switch
Mode," page 243) for instructions on setting this switch.)
In Foot Trip mode (Option Switch 3 OPEN), after you depress the Foot Switch, the press
runs for one stroke. To run the press, set the stroke select switch to FOOT. Then press the
Foot Switch. The press will run for one stroke and then will top stop.
In Foot Control mode(Option Switch 3 CLOSED), you must depress and hold the Foot
Switch through Auto Carry-up to single stroke the press. If you do not, the press stops
immediately. To run the press, set the stroke select switch to FOOT. Press and hold the
foot switch through the bottom of the stroke. The press will complete one stroke and then
will top stop.
5. Select FOOT in the mode select menu (page 365).
6. Turn the stroke select key to Single Stroke.
NOTICE
INTERRUPTED STROKE
In Foot Control, if you do not keep the foot switch fully depressed through the auto carry-up
angle, the Interrupted Stroke message will flash on the display and the press will stop. WPC
automatically reverts to TWO HAND MAINTAINED SINGLE STROKE mode for the
remainder of the stroke.
Page 372
SmartPAC 2 with WPC Integration
Chapter 6
SmartPAC 2 Run Mode