Check The Emergency-Stop Circuit - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800

Check the Emergency-Stop Circuit

!
DANGER
INJURY DURING TESTING
Keep all personnel away from the press during testing.
Ensure that there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
Run the press in Continuous mode, and depress the EMERGENCY STOP button. The press
should Emergency-stop immediately.
• If the press Emergency-stops, go to the next test.
• If the press does not Emergency-stop, there is a problem in your E-stop circuit.
Recheck all wiring and correct any problems. Re-run this test. If the press still does
not Emergency-stop, contact Wintriss Tech Support. Do not run the press or continue
with this checkout procedure until the press E-stops correctly.
NOTICE
CHECKING THE EMERGENCY-STOP CIRCUIT IN SINGLE STROKE MODE
If your press does not run in continuous mode, run this test while the press is making a
stroke in Single Stroke mode.