Figure 6 - 18. Using "Brake Monitor" Display For 90° Test - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

SmartPAC 2 with WPC Integration
TOOL NUMBER 1234567
CHAIR BRACKET
SENSORS ENABLED
STOP TIME
START TIME
STOP ANGLE
90 STOP
PRESS THE UP CURSOR KEY TO START THE
90 DEGREE BRAKE TEST.
PRESS THE RESET KEY WHEN DONE.
Figure 6 - 18. Using "Brake Monitor" Display for 90° Test
NOTICE
Before you can go into Run mode, a tool must be programmed and loaded in Program
mode. Consult Chapter 5 for assistance.
3.
Run the press in Continuous mode. If the press has a variable speed drive, set the speed
to the fastest that you will normally run.
4.
Press the UP cursor key to start the 90° stop-time test. The message at the bottom of the
display will now say:
90 DEGREE BRAKE TEST ARMED
PRESS RESET TO CANCEL TEST
5.
The next time that the press reaches 90°, the emergency stop relays will open and stop
the press.
6.
Record the information displayed on the LCD display. The stop time value is displayed
in milliseconds. One millisecond = 1/1000th of a second =.001 sec.
7.
Repeat the test at least 5 more times. Record the highest reading from all your tests. This
is the stop time value to use when calculating safety distance.
8.
Press RESET when done to be returned to the Main Run menu.
For HELP press the HELP key located at the center of the cursor (arrow) keys.
SmartPAC 2 Run Mode
PART CNTR
STOP TIME STATUS
VALUE (MSEC)
250
155
75
0
Chapter 6
0
LIMIT (MSEC)
300
200
75
1126800
page 347