Dsv Interface And Lockout Relay Failures - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

SmartPAC 2 with WPC Integration

DSV Interface and Lockout relay failures

Problem:
These errors indicate failures that have occurred in the DSV interface.
Note that #72 through #76 can also be generated by the second processor.
The errors are as follows:
F70
The first (DSV-A) DSV relay driver did not open at start of stroke
F71
The two DSV relay drivers have shorted together
F72 or H72
The DSV control flip-flop not functioning properly
F73 or H73
The DSV missing pulse detector window not functioning properly
F74 or H74
The DSV relay driver did not close properly at the start of the stroke
F75 or H75
The DSV relay driver did not open properly at the end of the stroke
F76 or H76
The Lockout relay driver did not open properly at the end of the stroke
F77 or H77
The Lockout relay check contacts were not closed before the lockout relay
was turned on. Check fuse F402 on the WPC power supply board.
Remedy:
Reset. If you still get these errors, contact Wintriss Tech Support for
assistance or replacement.
SmartPAC 2 Fault Messages
70* through 76*
Chapter 7
1126800