Anti-Tiedown Test - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800

Anti-tiedown Test

!
DANGER
INJURY DURING TESTING
Keep all personnel away from the press during testing.
Ensure that there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
OPERATOR STATION MAY NOT MEET SAFETY REQUIREMENTS
Ensure that the operator station is wired correctly.
Ensure that on any non-Wintriss operator station run buttons are placed so that two hands
are required to push both buttons at the same time and no one can press both buttons with
one hand or with one hand and one elbow or in any other way.
Ensure that on any non-Wintriss operator station the run buttons have guard rings or other
means in place to prevent unintentional operation.
Failure to comply with these instructions will result in death or serious injury.
Perform the following test to verify that the operator station is correctly installed and wired
to require two hands to press both run buttons simultaneously.
1. Set the STROKE SELECT switch to SINGLE STROKE.
2. Press and hold down both run buttons. The press cycles to makes one stroke.
3. While still holding down the left button, do the following: Remove your right hand from
the right button for a moment. Then press the right button again. The press should not
cycle again.
• If the press does not cycle, go to the next step to perform the test for the other side.
• If the press does cycle, check the wiring. Repeat the test starting with step 2. If the
press still cycles, contact Wintriss Tech Support.
4. Remove hands from the buttons. Then press and hold down both run buttons. The press
makes a stroke.
5. While still holding down the right button, do the following: Remove your left hand from
the left button for a moment. Then press the left button again. The press should not cycle
again.
• If the press does not cycle, your anti-tiedown test is complete. Go to the next test.
• If the press does cycle, check the wiring. Repeat the test starting with step 4. If the
press still cycles, stop! Turn off the press. Contact Wintriss Tech Support.