Setting Auto Carry-up Angle

7. Go to the SmartPAC's Main Initialization menu (Figure 4 - 1), and select "Press Control."
The WPC Initialization menu appears. Select "Press Options." In the menu that appears,
set Switch 7 to OPEN to enable changes (see page 247). Power down SmartPAC 2 with
WPC and power it up again to make the new switch setting take effect.
8. Go to the SmartPAC's Main Initialization menu (Figure 4 - 1), and select "Press Control."
The WPC Initialization menu appears. Select "Press Parameters." Use the cursor keys to
highlight "Carry-up Angle" in the display shown below. Then press ENTER to select.
USE THE CURSOR KEYS TO CHOOSE THE VALUE
YOU WANT TO CHANGE.
PRESS THE ENTER KEY TO CHANGE THE VALUE.
PRESS THE RESET KEY WHEN DONE.
Figure 4 - 30. Selecting "Auto Carry-up Angle"
9. Use the number keys to enter the new value, and then press ENTER.
10. Press RESET twice when you are done, and you will return to the Initialization menu.
11. Go to the SmartPAC's Main Initialization menu (Figure 4 - 1), and select "Press Control."
The WPC Initialization menu appears. Select "Press Options." In the menu that appears,
set Switch 7 to CLOSED to disable changes to Auto Carry-up angle (see page 247).
Power down SmartPAC 2 with WPC and power it up again to make the new switch
setting take effect.

Setting Micro-Inch Time and Angle (Optional)

Follow the instructions in this section to set Micro-inch Time and Micro-inch Angle (also
known as "Micro-inch ON Angle"). These apply to operation in Inch mode only.
Micro-inch time is the amount of time in milliseconds that the Dual Safety Valve is open
each time you push the Run/Inch buttons in Inch mode. You can set the Micro-inch time to 6
to 600 milliseconds. The press operates the same way that it does during TOP STOP INCH.
Page 236
PRESS CONTROL PARAMETER MENU
TOP STOP DEFLT
=
CARRYUP ANGLE
=
MICRO TIME
=
MICRO ANGLE
=
MAIN AIR LIMIT
=
CNTR BAL +/-
=
STOP LIMIT
=
START LIMIT
=
SHUT DOWN LIMIT
=
FLYWHEEL TIMER
=
ACTS ANGLE
=
INITIALIZE PARAMETERS
Chapter 4
SmartPAC 2 with WPC Integration
220 DEG
149
149 DEG
100 MSEC
185 DEG
0 PSI
0 PSI
250 MSEC
199 MSEC
5 MIN
6 SEC
0 DEG