Starting with this display, you can access all the other displays in Initialization mode.
The Initialization menu choices for the basic SmartPAC 2, plus ProCamPAC and DiProPAC
are described in the sections below.
NOTICE
SET THE INTERNAL CLOCK IN SMARTPAC 2
When you initialize your SmartPAC 2, be sure to set the clock to the correct date and your
local time according to the instructions at "SET CLOCK," page 266.
Initialize WPC Press Parameters
NOTICE
Initializing the press control parameters resets them to their default settings. Initialize the
press parameters only when you set up a new SmartPAC 2 with WPC or install new
SmartPAC 2 firmware.
NOTICE
RECORD YOUR WPC SETTINGS BEFORE YOU INSTALL NEW WPC FIRMWARE AND
INITIALIZE WPC (PRESS) PARAMETERS
Use the WPC Parameters setup sheets at the end of this manual to record the parameters
before you initialize WPC parameters. See Chapter 2, page 101.
When you first set up your SmartPAC 2 with WPC or install new WPC firmware, initialize
the press parameters by following the steps starting on page 101, "Initialize Press
Parameters."

RESOLVER ZERO

(INITIALIZATION – RESOLVER ZERO)
Zeroing the resolver is discussed in detail in "Zero the Resolver," page 105 in Chapter 2.
If you replace your resolver with a new one (installation steps are discussed in "Install the
Resolver," page 41, Chapter 2), you will need to rezero the resolver. This is discussed in "If
You Replace Your Resolver," page 43.
Page 204
SmartPAC 2 with WPC Integration
Chapter 4
SmartPAC 2 Initialization Mode