Miscellaneous Fault Messages - Honeywell SmartPAC 2 User Manual

Press automation control with wintriss wpc clutch/brake control
Table of Contents

Advertisement

1126800
Fault message for red sensors "This N/C sensor is open"
Explanation:
A red sensor has actuated (is open to ground). When this message appears,
the angle where the condition was detected is also listed shown on the
LCD display.
Remedy:
Check for the press or equipment malfunction that the sensor was
supposed to detect. If none has occurred, check for a malfunctioning
sensor. Check for loose or detached wiring at the remote connection box
or controller. Check for a severed wire from the sensor to the RCB or
controller.

Miscellaneous Fault messages

"Maximum press speed exceeded"
Explanation:
This message is generated when the press is running at a speed greater
than the maximum limit set at SmartPAC 2.
Remedy:
After clearing the error, either run the press at a slower speed, or adjust the
maximum limit set at SmartPAC 2. Refer to Chapter 4.
"Minimum press speed exceeded"
Explanation:
This message is generated when the press is running at a speed less than
the minimum limit set at SmartPAC 2.
Remedy:
After clearing the error, either run the press at a higher speed, or adjust the
minimum limit set at SmartPAC 2. Refer to Chapter 4.
"stop"
Explanation:
This message is only generated when SmartPAC 2 is communicating with
PACNet Computerized Pressroom Reporting software. The user at the
computer has sent a top stop command to that SmartPAC 2. When this
occurs, SmartPAC 2 in turn stops the press.
Remedy:
Because this condition was generated by someone at the computer, it is
important to investigate the reason why the stop command was issued. A
problem may be present. Check with personnel before proceeding. After
the situation is clear, press RESET to continue.
Page 416
SmartPAC 2 with WPC Integration
Chapter 7
SmartPAC 2 Fault Messages