NOTE 1: CONNECT THE SHIELD TO THE
ENCLOSURE CLOSE TO THE CONDUIT
ENTRY POINT.
NOTE 2: CUT THESE WIRES OFF CLOSE
TO THE END OF THE CABLE JACKET.
THE WHITE, TAN AND PINK WIRES ARE NOT USED SEE NOTE 2.
1
TB551
302 (Relay Pwr)
303 (Aux 4)
DiProPAC 16
304 (Aux 3)
305 (Aux 2)
TB550
306 (Aux 1)
TB552
1
1
2 WIRE DC PROX. SENSOR
+24 VDC
2
+ Signal
1.2 K
GND
3
- Signal
SENSOR IN
4
N.C.
1.2K IS A TYPICAL VALUE
(SEE INSTRUCTIONS FOR DETAILS)
PNP PROX. SENSOR
1
+VDC
+24 VDC
2
GND
GND
3
OUT
SENSOR IN
4
N.C.
1
+24 VDC
2
GND
3
SENSOR IN
4
N.C.
TYPICAL FOR MECHANICAL SENSORS.
USE THIS FOR MECHANICAL SWITCHES
AND SWITCHED PROBES.
SEE NOTE 1
SENSORS 1 - 8
SEE NOTE 1
CUSTOMER SUPPLIED
12 VDC SOLID-STATE
RELAY
+ INPUT
OUTPUT
- INPUT
OUTPUT
1
THIS OUTPUT WILL TURN ON WHEN THE DIPRO
SENSORS ARE DISABLED. IT IS AN OPEN COLLECTOR
TYPE OUTPUT AND CAN SINK 8 MA. TO GROUND.
SENSORS 9 - 16
SEE NOTE 1
SEE NOTE 1
1
+VDC
NPN PROX. SENSOR
+24 VDC
2
GND
GND
3
OUT
SENSOR IN
4
N.C.
1
+24 VDC
2
GND
3
SENSOR IN
4
N.C.
USE THIS FOR UNSWITCHED PROBES.
THESE PROBES ARE GROUNDED BY THE
PART OR THE PRESS FRAME.
REV
3
2
1
TB3
DSI 2
SENSOR STATUS
1
2
3
4
5
6
7
8
POWER
OUTPUT
INPUT
1
BRN
1
Sensor 1
Sensor 1
2
2
RED
Sensor 2
Sensor 2
3
3
ORG
Sensor 3
Sensor 3
4
4
YEL
Sensor 4
Sensor 4
5
2
3
5
GRN
Sensor 5
Sensor 5
6
6
BLUE
Sensor 6
Sensor 6
7
1
4
VLT
7
Sensor 7
Sensor 7
1 - Sensor Power˜
8
8
GRY
Sensor 8
Sensor 8
2 - Ground
9
9
BLK
Grd
3 - Sensor Input
Grd
10
10
4 - N.C.
Grd
Grd
11
11
+5 VDC
+24 VDC
12
+24 VDC
TB2
TB4
3
2
1
TB3
DSI 2
WARNING: WHEN USING TWO DSI 2 UNITS,
DO NOT CONNECT THE 24 VDC OUTPUTS
FROM THE UNITS TOGETHER.
SENSOR STATUS
1
2
3
4
5
6
7
8
POWER
OUTPUT
INPUT
1
BRN
1
Sensor 1
Sensor 1
2
2
RED
Sensor 2
Sensor 2
3
3
ORG
Sensor 3
Sensor 3
4
4
YEL
Sensor 4
Sensor 4
5
2
3
5
GRN
Sensor 5
Sensor 5
6
6
BLUE
Sensor 6
Sensor 6
7
1
4
VLT
7
Sensor 7
Sensor 7
1 - Sensor Power˜
8
8
GRY
Sensor 8
Sensor 8
2 - Ground
9
9
BLK
Grd
3 - Sensor Input
Grd
10
10
4 - N.C.
Grd
Grd
11
11
+5 VDC
+24 VDC
12
+24 VDC
TB2
TB4
DRAWN
DATE
ADB
7/18/03
CHK.
APPROVALS
TITLE
ENG.
DiProPAC to DSI 2 Wiring Diagram
MFG.
CODE IDENT NO.
FILENAME
REL
SCALE
NONE
REVISIONS
DESCRIPTION
DATE
APP'D
GND
L2
120 VAC
L1
HONEYWELL
ACTON MA.
DRAWING NUMBER
REV
SIZE
C
FIGURE 10
SHEET
OF

Hide quick links: