ECP Status Codes

When the IGSMHS is configured for ECP mode, it sends status messages to the control
panels for battery, power, tamper, and network connectivity failures. Some control panels
display these on the keypad as "LngRng Radio" followed by a 4-digit code (listed in the table
below). In addition, the Contact ID codes (listed in Appendix B) for these conditions are sent
to the central station by the module.
UL
STATUS CODE
0000
0880
4005
000F
0019
0400
0C80
0C8F
08E0
3000
8000
0060

Alternative Modes (Zone Trigger, 4204 and Two-4204)

U L

Zone Trigger Mode

There are six input zones available on the IGSMHS. Each zone is selectable for +V, -V, or
EOLR trigger. The first zone input can detect both pulsed and steady signals if connected to
a bell output. Additionally, the first zone input can be programmed to detect a single pulse
(characteristic of a Panic indication on the Lynx, LynxR or LynxR-EN control panel by
enabling the Lynx Panic option). If the programming option "Lynx Panic" is enabled, the
IGSMHS reports an alarm on zone 3. No restores are reported for this zone. If this option is
selected, the second physical zone input is ignored.
ENTRY
OPTIONS
[Y] = review
[N] = exit
The information in the following table is based on the VISTA-20 which has not been evaluated
with this communication module.
Table 3-3. Common ECP Keypad Display Status Codes
Control panel lost communication with IGSMHS.
IGSMHS tamper detected (cover removed).
IGSMHS has lost contact with AlarmNet.
IGSMHS is not registered; account not activated.
IGSMHS shutdown.
IGSMHS power on / reset AND the control panel lost communications with IGSMHS.
IGSMHS power on / reset AND tamper detected.
IGSMHS power on / reset AND tamper detected AND not registered.
IGSMHS tamper detected and IGSMHS battery low.
Primary power loss (will only be displayed in conjunction with another event).
Battery charger failure (will only be displayed in conjunction with another event).
Low battery (will only be displayed in conjunction with another event).
The LYNX controls have not been evaluated with this communication module.
Section 3: Programming the IGSMHS
DESCRIPTION
Reviewing Programming Mode Entries
To review the programming options (to ensure that
the correct entries have been made), press [Y]. The
programming prompts are displayed again. Use the
up/down arrow keys to scroll through the program
fields without changing any of the values. If a value
requires change, simply type in the correct value.
When the last field is displayed, the "REVIEW?"
prompt again appears.
To exit the programming mode, press [N] in
response to the "REVIEW?" prompt, and refer to
Exiting Programming Mode at the end of this section.