Configuring Univerge Um8500 Ports - NEC UNIVERGE UM8500 Integration Manual

Hide thumbs Also See for UNIVERGE UM8500:
Table of Contents

Advertisement

To configure LAN MCI parameters
1
Shut down UNIVERGE UM8500 before setting the following parameters.
2
Start
Programs
Click
>
Utility
.
3
Ensure the current phone system file is correct and then click
Switch Configuration
4
In the Switch Configuration window, click the
5
In the PBX Connection Settings section, enter the IP address of the phone
system that provides UNIVERGE UM8500 server with the integration data.
6
Enter the type of parity check used for LANMCI module in phone system, this
can be odd or even, in
through b4.
7
Enter the ID number of a free LANMCI device in
2400 and SV7000 offer 2 devices (
receive MCI (Message Center Interface) data from either.
8
If the phone system is configured to use office codes for internal extensions,
the office code must be entered in the
Prefixes
fields of the
whether the phone system uses office codes:
Use command ASYD, confirm that index 240, bit b4 is set to 0.
Write down the office code that the phone system uses for internal calls.
Check to see if the phone system is not set to remove the office code from
MCI packets, see the ASYD command, index 370, bit b1 is set to 0.
Edit Switch Utility
Return to
recorded above in the
Prefixes
field. Otherwise, leave the two edit boxes blank (ASYD, index
240, bit b4 is not set to 0 or ASYD, index 370, bit b1 is not set to 0).
NOTE
An office code is usually introduced to distinguish the extensions
of different phone systems that communicate through a CCIS
connection. This office code can not be dialed; it appears only in
the integration data and on the screen display of the phones for
calls over CCIS.
9
Leave the other settings at the default values and then click
changes and close Edit Switch utility.

Configuring UNIVERGE UM8500 ports

Configure the UM8500 voice ports. The procedure used depends on the port type
the system is using.
For IP-VPS or IP Terminal ports, see
ports"
on page
190.
For analog, T1, or digital ports, see
on page
190.
NEC NEAX 2400
OR
UNIVERGE UM8500 group
>
.
Integration
Parity
field. See the command ASYD, index 34, b1
0
1
and
) and UM8500 can connect and
Ignored Prefixes
Edit Switch Utility > Integration
Integration
>
Ignored Prefixes
field and
"To configure IP-VPS or IP Terminal
"To configure Analog, T1 or Digital
NEC SV7000
LAN MCI
WITH
Edit Switch
>
Edit this
tab.
Device ID
field. NEC NEAX
Ignored VM
and
tab. To check
tab. Enter the office code
Ignored VM
OK
to save the
ports"
189

Advertisement

Table of Contents
loading